The dialog contains one list box at the bottom to select output time units. The SIMPROCESS time clock runs in the time unit selected in the Run Settings (which defaults to Hours). However, for output to the Standard Report or Database, Nanoseconds, Microseconds, Milliseconds, Seconds, Minutes, Hours, Days, or Weeks may be selected. The Standard Report can be viewed with different output time units without rerunning the simulation (provided the model is not closed). Simply select a different time unit, then display the Standard Report again.
Check Boxes
Collect Activity Statistics
This check box requests statistics for every activity and process in a model. Selecting this option overrides individual activity statistics selected. This option should not be used for models with a large number of activities.
Collect Entity Statistics
This check box requests statistics for all entities defined in the model. Selecting this option overrides individual entity statistics selected. This option is default for new models.
Collect Resource Statistics
This check box requests statistics for all resources defined in the model. Selecting this option overrides individual resource statistics selected. This option is default for new models.
Collect Connector Statistics
This check box requests statistics for all connectors defined in the model. Selecting this option overrides individual connector statistics selected. This option is off for new models and should be used with great care. See Chapter 8 of the SIMPROCESS User's Manual for more information.
Collect Resource by Activity Statistics
This check box requests resource by activity statistics for all resources defined in the model. Selecting this option overrides individual resource by activity statistics selected. This option should not be used for models with a large number of activities with resources.
Collect Resource by Shift Statistics
This check box requests resource by shift statistics for all resources defined in the model. Selecting this option overrides individual resource by shift statistics selected.
Collect Activity by Entity Statistics
This check box requests activity by entity statistics for all activities in the model. Selecting this option overrides individual activity by entity statistics selected. This option should not be used for models with a large number of activities.
Collect Connector by Entity Statistics
This check box requests connector by entity statistics for all connectors defined in the model. Selecting this option overrides individual connector by entity statistics selected. This option is off for new models and should be used with great care. See Chapter 8 of the SIMPROCESS User's Manual for more information.
Generate Standard Report after run
This check box causes the Standard Report file to be generated automatically after a simulation run. This is most useful when using the Experiment Manager or optimization. Note that Standard Reports generated automatically are not accessible from within SIMPROCESS. The file (which is located in the model's directory) must be opened separately
Buttons
Clear Individual Statistics Requests
Each type of statistic request has a button to clear any local requests. The button is only active when the global option is not selected. The action taken by any button is immediate and cannot be undone by using the Cancel button to dismiss this dialog.